Description of functions:
● Wall mounting, protection IP 65
● DC side
o Prepared for 2 strings o Surge arrester T1+T2
o Fuses 16A
● AC side
o Main switch
o Overvoltage protection input T1+T2
3
o Inverter fuse 3x20A
o HDO – emergency disconnection of the inverter (NO, NC) o Network quality monitoring (L1, L2, L3 and N)
● AC side Advance
o Manual switching Network, Backup (Max. 10 kW), Off
o Additional protection with a current protector
o Protection of backup output 3x16A
o Blocking of electric heating (boiler, boiler, floor unit) o Shorted-out backup socket
● Suitable for SAJ, GoodWe, Solax, Growatt inverters up to 10kW
● House fuse up to 40A
● Simple installation, only a loop from the house switchboard min. CYKY-J 4x6mm (recommended
CYKY-J 4x10mm)
● Optional
o Set of drawers for Backup
Compact design for quick installation.
The cabinet is equipped with screwless terminals
Components only from verified manufacturers SCHRACK, HAGER, ELKO EP
Gallery